HY»çÀ̾𽺠½ÃÀÛÆäÀÌÁö·Î      Áñ°Üã±â µî·Ï
   ÇöÀçÀ§Ä¡ : HOME >   >    >  

¸¶ÀÌÅ©·ÎÅè, Microtomes SC4500
±Ô°ÝÀ» ¼±ÅÃÇØÁֽñ⠹ٶø´Ï´Ù ,¾Ç¼¼¼­¸®º°µµ

ÆÇ¸Å°¡°Ý  : [VATÆ÷ÇÔ]
Á¦Á¶»ç  : TBS   
ºê·£µå  : TBS   
¿ø»êÁö  : USA   
Á¦Ç°»óÅ  :
»óǰÄÚµå SC4500
»óǰ±Ô°Ý ÆÄ¶óÇÉ¿ë ºÐÇØ´É·Â
Ư±â»çÇ×1
Ư±â»çÇ×2

ÁÖ¹®¼ö·®  :
°³



 Microtomes SC4500  ¸¶ÀÌÅ©·ÎÅè









Section Counter LCD read-out of # revolutions & total amount advanced. Reset with a push of a button.
Sectioning/Trimming Settings 0.0- 2.0, in 0.5¥ìm increments

2.0-10, in 1.0¥ìm increments

10-20, in 2.0¥ìm increments

20-60 in 5.0¥ìm increments100 – 600 in 50¥ìm increments
Horizontal Specimen Advance 20mm ¡¾ 1mm, via stepper motor
Vertical Cutting Stroke 70mm ¡¾ 1
Automatic Retraction  Yes, can be turned off
Specimen Clamp Quick-Release Type for standard & biopsy cassettes, forward/backward spring tensioned operating lever.
Specimen Orientation X/Y Axes 8¡Æ Z Axis 360¡Æ
Specimen Arm Locking Handwheel locking of specimen in uppermost positionSecondary 360¡Æ locking mechanism
Motorized Specimen Feed Two-speed forward & return: 270 ¥ìm/sec or 1055 ¥ìm/sec
Motorized Cutting Speed Variable speed forward & return: 100 ¥ìm/sec to 400 ¥ìm/sec
Blade Holder Disposable Blade Holder for Low-Profile Blades with Lateral Displacement Feature
Permissible Storage Temp. Range 5¡ÆC to 55¡ÆC
Dimensions: mm (inches) Depth 550 (22)

Width 420 (17)Height 320 (13)
Weight: kg (lbs) Microtome 38 (99)Microtome, crated 46 (101)
Manual Operation Yes
Push-Button Switching Membrane switching between Trimming & Sectioning
Motorized Operation  Hand-pad control of hand-wheel speed between30-120rpm, with Continuous & Single stroke operating modes
Foot Pedal Control For single stroke and continuous operation,Stop Action (Single tap)
Electrical Requirements 100-120VAC, 50/60Hz, 77W; 220-240VAC, 50/60Hz, 77W
Accessories Included

Specimen Orientation Mechanism, Quick-Release Clamp; Disposable Blade Holder for low profile blades; 1-PK of low profile blades (DMB-LP); Section Waste Tray, Dust Cover, Tool Kit, Lubrication Kit, Operator Manual and a sample bottle of PARA/Gard¢â

Foot Pedal

* ¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆÇ¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.


±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó, »çÀÌÁî, ´Ù¸¥»óǰ±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ¿Õº¹¹è¼Ûºñ °í°´ºÎ´ã ÀÔ´Ï´Ù.

!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óǰ °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹Ýǰ½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
°áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óǰÀ» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
¼öÀÔÁ¦Ç°ÀÇ °æ¿ì Àç°í¾øÀ» ½Ã 30ÀÏ Á¤µµ ¼Ò¿äµË´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìÄÎ Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±ÝÀÌ °¡´É ÇÔ´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
¾ÆÁ÷ ÀÛ¼ºµÈ »óǰÆòÀÌ ¾ø½À´Ï´Ù.
 
0 EA
no img
»ó´ã½Ã°£ ÆòÀÏ 09:00 ~ 18:00 Åä¿äÀÏ ÁÖÀÏ,°øÈÞÀÏ ÈÞ¹« ÆÑ½º 032-571-4445
»ó´ã ¹× ¹®ÀÇÀüÈ­ 032-471-8801~2 ( 0093hy@naver.com )
ÀԱݰèÁ¾ȳ» : ±¹¹ÎÀºÇà 223301-04-296256 (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷
»óÈ£ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷|ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ
»ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 (Á¤º¸È®ÀÎ)| Åë½ÅÆÇ¸Å¾÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£|
´ëÇ¥ : | °³ÀÎÁ¤º¸ °ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤| °³ÀÎÁ¤º¸ º¸È£±â°£ : ȸ¿øÅ»Åð½Ã