¿À´Ã º» »óǰ (0)
    no
    show
    °ßÀû¹®ÀÇ
    ½Ç½Ã°£°ßÀû
    ±â¼úÀÚ·á½Ç
    °øÁö»çÇ×
    Áú¹®°ú ´äº¯
    °í°´¼¾ÅÍ
    T.032-471-8801~2
    ¿ù - ±Ý : 09:00 ~ 18:00
    Á¡½É : 12:00 ~ 13:00
    Åä, ÀÏ, °øÈÞÀÏ ÈÞ¹«
    °í°´¼¾ÅÍ ¿¬°áÀÌ Àß µÇÁö¾ÊÀ»½Ã
    Q&A °Ô½ÃÆÇÀ» ÀÌ¿ëÇØÁÖ¼¼¿ä.

    ÀüÀ§Â÷ ÀûÁ¤±â, T5 ET, T5 ETR, T7, T9
    ÆÇ¸Å°¡°Ý °¡°Ý¹®ÀÇ
    ¿ø»êÁö ½ºÀ§½º
    ºê·£µå Mettler-Toledo
    Á¦Ç°ÄÚµå T5 ET, T5 ETR, T7, T9
    º»Ç°¿É¼Ç¼±Åà  
    »ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦

    • Titration Excellence Line
    • ÀüÀ§Â÷ ÀûÁ¤±â

    °ÅÀÇ ¸ðµç ºÐ¾ß¿¡ ÀûÇÕÇÔ (Food, Pharma, Chemistry), ÇÑ±Û Áö¿ø°¡´É
     »ç¿ëÀÚ°¡ ÀÚÁÖ »ç¿ëÇÏ´Â ½ÇÇè¹ýµîÀ» ´ÜÃàŰ (Shortcut)·Î ¸¸µé¾î ÇѹøÀÇ Å¬¸¯À¸·Î ºÐ¼® ½ÃÀÛ °¡´É
     Àü±Ø, ºä·¿, Ãß°¡ DriveµîÀÇ ÁÖº¯±â±â ÀÚµ¿ÀνÄ
     ¹à°í ¼±¸íÇÑ TFT ÅÍÄ¡ ½ºÅ©¸°
     °¢°¢ÀÇ »ç¿ëÀÚº° Homescreen ±¸¼º °¡´É
     °ËÁõµÈ 60°³ ÀÌ»óÀÇ Mettler Toledo MethodÀúÀå (T5 : 15ea, T7 : 60ea, T9 : 150ea)
     USB, Ethernet, CAN-BUS ÀÎÅÍÆäÀ̽º ±âº»Á¦°ø
     Rondolino Auto Sampler ÀåÂø °¡´É
     ¸ðµç ÀÀ¿ë¿¡ Àû¿ë °¡´ÉÇÑ ´Ù¾çÇÏ°í °ß°íÇÑ ÀûÁ¤±â¿ë Àü±Ø »ç¿ë °¡´É


     

     

    ±âº»Çü (The Convenient and Versatle)

    Model

    Burette Drive

    Package

    T5 ET

    Max. 2ea

    w/ Manual Stand

    T5 ETR

    w/ ondolino Stand

     

     ºÐÁÖ¸¦ À§ÇÑ Burette Drive¸¦ 2°³±îÁö È®Àå °¡´É
     pH Board¸¦ Conductivity Board·Î ½±°Ô ±³Ã¼ °¡´É
     USB, Ethernet, CAN-BusÀÎÅÍÆäÀ̽º Á¦°ø
     T5 ET : T5 Main Unit, Terminal, 10 ml Burette, Compact Stirrer, Manual Titration Stand Kit
     T50A Terminal : T5 Main Unit, Terminal, 10 ml Burette, Compact Stirrer, Automated Titration Stand Rondolino

     

    ´Ù±â´É ÀûÁ¤±â (Flexible and Expandable)

    Model

    Burette Drive

    T7

    Max. 4ea

     

    ºÐÁÖ ¹× ÀûÁ¤¿ëµµÀÇ Burette Drive¸¦ 4°³±îÁö È®Àå °¡´É
     Sensor Board ¸¦ 1°³ ´õ È®Àå ÇÒ ¼ö ÀÖ¾î pH¿Í Àüµµµµ ÃøÁ¤À» µ¿½Ã¿¡ ÇÒ ¼ö ÀÖÀ½
     T9 À¸·Î ¾÷±×·¹À̵尡 °¡´ÉÇÔ
     ¼­·Î ´Ù¸¥ ´Ù¾çÇÑ ÀϵéÀ» µ¿½Ã ÁøÇà °¡´É
     T7 : T7 Main Unit, Terminal, pH Board, 10ml Burette

     

    ´Ù±â´É ÀûÁ¤±â (Intelligent and Powerful)

     

    Model

    Burette Drive

    T9

    Max. 8ea

     

    ºÐÁÖ ¹× ÀûÁ¤¿ëµµÀÇ Burette Drive¸¦ 8°³±îÁö È®Àå °¡´É
     Sensor Board ¸¦ 2°³ ´õ È®Àå ÇÒ ¼ö ÀÖ¾î pH¿Í Àüµµµµ ÃøÁ¤À» µ¿½Ã¿¡ ÇÒ ¼ö ÀÖÀ½
     µÎ°³ÀÇ ½ºÅÄµå ¶Ç´Â µÎ°³ÀÇ Rondo »ùÇ÷¯¸¦ ÀÌ¿ëÇÏ¿© ½ÇÇè¹ýÀÌ ´Ù¸¥ µÎ°¡Áö ½Ã·á±ºÀ» µ¿½Ã ÀûÁ¤ °¡´É
    ¡°If ~ Then¡±Á¶°ÇÀ¸·Î ºÐ¼®¹ý ÆíÁý °¡´É
     °¢°¢ ´Ù¸¥ ºÐ¼®¹ýÀÇ ´Ù¸¥ Á¾·ùÀÇ ½Ã·á ¿¬¼Ó ºÐ¼® °¡´É
     T9 : T9 Main Unit ,Terminal, pH Board, 10ml Burette

     

    Comparison Table Titration Excellence Line

     

    Model

    T5

    T7

    T9

    One Click Titration

    User Specific Homescreen with shortcuts

    Yes

    Shortcuts per user

    24

    KF Solvent Control

    Yes

    Hot Plug and Play

    Solvent Manager

    USB Printer

    USB Memory Stick

    USB Barcode Reader

    Security

    LevelSens

    LosStraight Fingerprint Reader

    Automation

    InMotion Autosamplers

     

    Liquid Handler

    -

    1

    2

     

    Rondolino automated titration stand

    Yes

     

    InMotion KF Oven Autosamplers

    -

    Yes

    Burette Drives

    Max. Number to dose and titrate

    1 (Internal) + 1 (External)

    1 (Internal) +3 External

    1 (Internal) +7 External

    Max. Number to dose Only

    + 2 External

    -

    -

    Mathod and Series

    Max. Number of user methods

    150

    Learn Titration

    Yes

    Karl Fischer Methods Volumetric

    V20S equivalent methods

    Yes

    Karl Fischer Methods Coulometric

    C20S equivalent methods

    Bromine Index Determination

    Yes

    Thermometric TAN

    Accormpanying Stating

    -

    Yes

    Ion Standard Addition

    Yes

    SmartChemical

    SmartSample

    Number of Method functions per method

    15

    60

    150

    Number of Loops per Method

    1

    3

    6

    Continuous Run

    -

    Yes

    If....then conditions

    -

    Result Buffer

    -

    Series Sequences

    -

    10

    Number of samples per series

    303

    Predefined METTLER TOLDE method

    >60

    >70 (Incl. KF Methods)

    Task List

    Number of Tasks

    10

    30

    Number of Tasks running in parallel

    -

    7

    8

    Online Help

    -

    Yes

    Parallel Titration Including KF

    -

    -

    Yes

    Expandable

    -

    -

    To T9

    -

    Status light and event sounds

    -

    Yes

    Data Export / Printing

    RS232, USB, Ethernet, PDF

    Parallel Titraion

    -

    -

    -

    Yes

    Sensor Boards

    pH / mV or Conductivity or Coulometry

    1

    2/1

    3/1

    Sensor Inputs

    Potentiometric

    2

    4/2

    6/2

    Polarized

    1

    2/1

    3/1

    Reference

    1

    2/1

    3/1

    PT1000

    1

    2/1

    3/1

    Conductivity

    1/0

    2/0

    3/0

    PC Software

    LabX Titration Connectivity : Express and Server

    Yes

    Homogenizer

    -

    TTL

    RS/TTL

    Languages

    -

    English / German / French / Spanish / Italian / Chinese / Russian / Polish / Korea / Portuguese

     

     

     

    Technical Specification

     

    Model

    T5

    T7

    T9

    Potentiometric Sensor Inputs

    Measurement Range

    ¡¾2000mV

    Resolution / Error Limit

    0.1mV / 0.2mV

    Polarized Sensor Input

    Measurement Range Ipol / Upol

    0 ~ 2000mV / 0~200uA

    Resolution Ipol / Upol

    0.1mV / 0.1uA

    Error Limit Ipol / Upol

    2.0mV / 0.2uA

    Current Source Range Ipol / Upol

    0~24uA AC / 0~2000mV AC

    Current Source Resolution Ipol / Upol

    0.1uA / 0.1mV

    Temp.

    Sensor PT1000

    Measuring Range

    -20~130¡É

    Resolution / Error Limit

    0.1¡É / 0.2¡É

    Burette Drive

    Burette Resolution (for 10ml Burette)

    0.5ul (1/20,000 of the burette volume)

    Error Limit

    0.2% of the butette volume

    Resolver Resolution

    0.0625% of butette volume

    Filling time and discharge time

    20s at 100% filling rate

    Titration Dimension

    w ¡¿ d ¡¿ h

    210¡¿246¡¿250mm

    Weight

    4.3kg

    Terminal

    Control

    Touch Control

    Screen

    WVGA 7" color TFT

    Resolution

    800¡¿480 pixel

     

    InMotion AutoSampler

     Mettler-Toledo ÀûÁ¤±â ¸ðµÎ InMotion AutoSampler¸¦ ÅëÇØ Çѹø¿¡ ¿©·¯ °³ÀÇ »ùÇÃÀ» ÀûÁ¤ÇÒ ¼ö ÀÖÀ½

     

    • InMotion Oven AutoSampler

    Model

    Description

    Capacity

    30407503

    KF Oven Autosampler

    5ml

    30407502

    10ml

    30407501

    20ml

     

     

    • ¿Àºì ÃßÃâ ±â´ÉÀ¸·Î ¼öºÐÀ» ÃøÁ¤Çϵµ·Ï ¼³°èµÊ. (40~280¡É)
    •  30407503 : 26¡¿5 ml ºÐ¼® °¡´É
       30407502: 24¡¿10 ml ºÐ¼®°¡´É
       30407501: 20¡¿20 ml ºÐ¼®°¡´É

    Model

    Description

    30094120

    InMotion Autosampler Flex (100ml ·¢Æ÷ÇÔ)

    30094122

    InMotion Autosampler Pro (100ml ·¢Æ÷ÇÔ)

    30094123

    InMotion Autosampler Max (100ml ·¢Æ÷ÇÔ)

     

    • 30094120 : 50¡¿25 ml, 27¡¿80 ml, 18¡¿100 ml, 15¡¿180 ml, 11¡¿250 ml
    •  30094122 : 182¡¿25 ml, 69¡¿80 ml, 34¡¿100 ml, 23¡¿180 ml
    •  30094123 : 303¡¿25 ml, 113¡¿80 ml, 55¡¿100 ml, 43¡¿180 ml, 24¡¿250 ml

    • Rondolino

    • Model

      Description

      51108500

      Sample Changer Rondolino

     

    ȸÀüÇü ÀûÁ¤ ½ºÅĵå : 9 samples + 1 conditioning beaker

     

     


     

     

    »óǰÁ¤º¸°í½Ã
    Á¦Ç°¸í ÀüÀ§Â÷ ÀûÁ¤±â, T5 ET, T5 ETR, T7, T9
    ÆÇ¸Å°¡°Ý °¡°Ý¹®ÀÇ
    ºê·£µå Mettler-Toledo
    ¿ø»êÁö ½ºÀ§½º
    °ü·Ã»óǰ
        
    »ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óǰÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óǰ¹®Àǰ¡ ¾ø½À´Ï´Ù.
      »óǰ¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
    ¹Ýǰ±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆÇ¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óǰ±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óǰ °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹Ýǰ½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óǰÀ» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ·Ôµ¥Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà Åù蹫·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)

    È­¹°(¿ë´Þ),Äü ÀÌ¿ëÀº ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷     ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ32     ´ëÇ¥ÀÚ : À±´ÙÀº, ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 (Á¤º¸È®ÀÎ)
    Åë½ÅÆÇ¸Å¾÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ : 121-86-02196     °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆÃ¼­ºñ½ºÁ¦°ø¾÷ü :