- Titration Excellence Line
- ÀüÀ§Â÷ ÀûÁ¤±â
°ÅÀÇ ¸ðµç ºÐ¾ß¿¡ ÀûÇÕÇÔ (Food, Pharma, Chemistry), ÇÑ±Û Áö¿ø°¡´É
»ç¿ëÀÚ°¡ ÀÚÁÖ »ç¿ëÇÏ´Â ½ÇÇè¹ýµîÀ» ´ÜÃàŰ (Shortcut)·Î ¸¸µé¾î ÇѹøÀÇ Å¬¸¯À¸·Î ºÐ¼® ½ÃÀÛ °¡´É
Àü±Ø, ºä·¿, Ãß°¡ DriveµîÀÇ ÁÖº¯±â±â ÀÚµ¿ÀνÄ
¹à°í ¼±¸íÇÑ TFT ÅÍÄ¡ ½ºÅ©¸°
°¢°¢ÀÇ »ç¿ëÀÚº° Homescreen ±¸¼º °¡´É
°ËÁõµÈ 60°³ ÀÌ»óÀÇ Mettler Toledo MethodÀúÀå (T5 : 15ea, T7 : 60ea, T9 : 150ea)
USB, Ethernet, CAN-BUS ÀÎÅÍÆäÀ̽º ±âº»Á¦°ø
Rondolino Auto Sampler ÀåÂø °¡´É
¸ðµç ÀÀ¿ë¿¡ Àû¿ë °¡´ÉÇÑ ´Ù¾çÇÏ°í °ß°íÇÑ ÀûÁ¤±â¿ë Àü±Ø »ç¿ë °¡´É


±âº»Çü (The Convenient and Versatle)
Model
|
Burette Drive
|
Package
|
T5 ET
|
Max. 2ea
|
w/ Manual Stand
|
T5 ETR
|
w/ ondolino Stand
|
ºÐÁÖ¸¦ À§ÇÑ Burette Drive¸¦ 2°³±îÁö È®Àå °¡´É
pH Board¸¦ Conductivity Board·Î ½±°Ô ±³Ã¼ °¡´É
USB, Ethernet, CAN-BusÀÎÅÍÆäÀ̽º Á¦°ø
T5 ET : T5 Main Unit, Terminal, 10 ml Burette, Compact Stirrer, Manual Titration Stand Kit
T50A Terminal : T5 Main Unit, Terminal, 10 ml Burette, Compact Stirrer, Automated Titration Stand Rondolino
´Ù±â´É ÀûÁ¤±â (Flexible and Expandable)
Model
|
Burette Drive
|
T7
|
Max. 4ea
|
ºÐÁÖ ¹× ÀûÁ¤¿ëµµÀÇ Burette Drive¸¦ 4°³±îÁö È®Àå °¡´É
Sensor Board ¸¦ 1°³ ´õ È®Àå ÇÒ ¼ö ÀÖ¾î pH¿Í Àüµµµµ ÃøÁ¤À» µ¿½Ã¿¡ ÇÒ ¼ö ÀÖÀ½
T9 À¸·Î ¾÷±×·¹À̵尡 °¡´ÉÇÔ
¼·Î ´Ù¸¥ ´Ù¾çÇÑ ÀϵéÀ» µ¿½Ã ÁøÇà °¡´É
T7 : T7 Main Unit, Terminal, pH Board, 10ml Burette
´Ù±â´É ÀûÁ¤±â (Intelligent and Powerful)
Model
|
Burette Drive
|
T9
|
Max. 8ea
|
ºÐÁÖ ¹× ÀûÁ¤¿ëµµÀÇ Burette Drive¸¦ 8°³±îÁö È®Àå °¡´É
Sensor Board ¸¦ 2°³ ´õ È®Àå ÇÒ ¼ö ÀÖ¾î pH¿Í Àüµµµµ ÃøÁ¤À» µ¿½Ã¿¡ ÇÒ ¼ö ÀÖÀ½
µÎ°³ÀÇ ½ºÅÄµå ¶Ç´Â µÎ°³ÀÇ Rondo »ùÇ÷¯¸¦ ÀÌ¿ëÇÏ¿© ½ÇÇè¹ýÀÌ ´Ù¸¥ µÎ°¡Áö ½Ã·á±ºÀ» µ¿½Ã ÀûÁ¤ °¡´É
¡°If ~ Then¡±Á¶°ÇÀ¸·Î ºÐ¼®¹ý ÆíÁý °¡´É
°¢°¢ ´Ù¸¥ ºÐ¼®¹ýÀÇ ´Ù¸¥ Á¾·ùÀÇ ½Ã·á ¿¬¼Ó ºÐ¼® °¡´É
T9 : T9 Main Unit ,Terminal, pH Board, 10ml Burette
Comparison Table Titration Excellence Line
Model
|
T5
|
T7
|
T9
|
One Click Titration
|
User Specific Homescreen with shortcuts
|
Yes
|
Shortcuts per user
|
24
|
KF Solvent Control
|
Yes
|
Hot Plug and Play
|
Solvent Manager
|
USB Printer
|
USB Memory Stick
|
USB Barcode Reader
|
Security
|
LevelSens
|
LosStraight Fingerprint Reader
|
Automation
|
InMotion Autosamplers
|
|
Liquid Handler
|
-
|
1
|
2
|
|
Rondolino automated titration stand
|
Yes
|
|
InMotion KF Oven Autosamplers
|
-
|
Yes
|
Burette Drives
|
Max. Number to dose and titrate
|
1 (Internal) + 1 (External)
|
1 (Internal) +3 External
|
1 (Internal) +7 External
|
Max. Number to dose Only
|
+ 2 External
|
-
|
-
|
Mathod and Series
|
Max. Number of user methods
|
150
|
Learn Titration
|
Yes
|
Karl Fischer Methods Volumetric
|
V20S equivalent methods
|
Yes
|
Karl Fischer Methods Coulometric
|
C20S equivalent methods
|
Bromine Index Determination
|
Yes
|
Thermometric TAN
|
Accormpanying Stating
|
-
|
Yes
|
Ion Standard Addition
|
Yes
|
SmartChemical
|
SmartSample
|
Number of Method functions per method
|
15
|
60
|
150
|
Number of Loops per Method
|
1
|
3
|
6
|
Continuous Run
|
-
|
Yes
|
If....then conditions
|
-
|
Result Buffer
|
-
|
Series Sequences
|
-
|
10
|
Number of samples per series
|
303
|
Predefined METTLER TOLDE method
|
>60
|
>70 (Incl. KF Methods)
|
Task List
|
Number of Tasks
|
10
|
30
|
Number of Tasks running in parallel
|
-
|
7
|
8
|
Online Help
|
-
|
Yes
|
Parallel Titration Including KF
|
-
|
-
|
Yes
|
Expandable
|
-
|
-
|
To T9
|
-
|
Status light and event sounds
|
-
|
Yes
|
Data Export / Printing
|
RS232, USB, Ethernet, PDF
|
Parallel Titraion
|
-
|
-
|
-
|
Yes
|
Sensor Boards
|
pH / mV or Conductivity or Coulometry
|
1
|
2/1
|
3/1
|
Sensor Inputs
|
Potentiometric
|
2
|
4/2
|
6/2
|
Polarized
|
1
|
2/1
|
3/1
|
Reference
|
1
|
2/1
|
3/1
|
PT1000
|
1
|
2/1
|
3/1
|
Conductivity
|
1/0
|
2/0
|
3/0
|
PC Software
|
LabX Titration Connectivity : Express and Server
|
Yes
|
Homogenizer
|
-
|
TTL
|
RS/TTL
|
Languages
|
-
|
English / German / French / Spanish / Italian / Chinese / Russian / Polish / Korea / Portuguese
|
Technical Specification
Model
|
T5
|
T7
|
T9
|
Potentiometric Sensor Inputs
|
Measurement Range
|
¡¾2000mV
|
Resolution / Error Limit
|
0.1mV / 0.2mV
|
Polarized Sensor Input
|
Measurement Range Ipol / Upol
|
0 ~ 2000mV / 0~200uA
|
Resolution Ipol / Upol
|
0.1mV / 0.1uA
|
Error Limit Ipol / Upol
|
2.0mV / 0.2uA
|
Current Source Range Ipol / Upol
|
0~24uA AC / 0~2000mV AC
|
Current Source Resolution Ipol / Upol
|
0.1uA / 0.1mV
|
Temp.
Sensor PT1000
|
Measuring Range
|
-20~130¡É
|
Resolution / Error Limit
|
0.1¡É / 0.2¡É
|
Burette Drive
|
Burette Resolution (for 10ml Burette)
|
0.5ul (1/20,000 of the burette volume)
|
Error Limit
|
0.2% of the butette volume
|
Resolver Resolution
|
0.0625% of butette volume
|
Filling time and discharge time
|
20s at 100% filling rate
|
Titration Dimension
|
w ¡¿ d ¡¿ h
|
210¡¿246¡¿250mm
|
Weight
|
4.3kg
|
Terminal
|
Control
|
Touch Control
|
Screen
|
WVGA 7" color TFT
|
Resolution
|
800¡¿480 pixel
|
InMotion AutoSampler
Mettler-Toledo ÀûÁ¤±â ¸ðµÎ InMotion AutoSampler¸¦ ÅëÇØ Çѹø¿¡ ¿©·¯ °³ÀÇ »ùÇÃÀ» ÀûÁ¤ÇÒ ¼ö ÀÖÀ½
- InMotion Oven AutoSampler
Model
|
Description
|
Capacity
|
30407503
|
KF Oven Autosampler
|
5ml
|
30407502
|
10ml
|
30407501
|
20ml
|
- ¿Àºì ÃßÃâ ±â´ÉÀ¸·Î ¼öºÐÀ» ÃøÁ¤Çϵµ·Ï ¼³°èµÊ. (40~280¡É)
- 30407503 : 26¡¿5 ml ºÐ¼® °¡´É
30407502: 24¡¿10 ml ºÐ¼®°¡´É
30407501: 20¡¿20 ml ºÐ¼®°¡´É
Model
|
Description
|
30094120
|
InMotion Autosampler Flex (100ml ·¢Æ÷ÇÔ)
|
30094122
|
InMotion Autosampler Pro (100ml ·¢Æ÷ÇÔ)
|
30094123
|
InMotion Autosampler Max (100ml ·¢Æ÷ÇÔ)
|
- 30094120 : 50¡¿25 ml, 27¡¿80 ml, 18¡¿100 ml, 15¡¿180 ml, 11¡¿250 ml
- 30094122 : 182¡¿25 ml, 69¡¿80 ml, 34¡¿100 ml, 23¡¿180 ml
- 30094123 : 303¡¿25 ml, 113¡¿80 ml, 55¡¿100 ml, 43¡¿180 ml, 24¡¿250 ml
-
Model
|
Description
|
51108500
|
Sample Changer Rondolino
|
ȸÀüÇü ÀûÁ¤ ½ºÅĵå : 9 samples + 1 conditioning beaker
»óǰÁ¤º¸°í½Ã
Á¦Ç°¸í |
ÀüÀ§Â÷ ÀûÁ¤±â, T5 ET, T5 ETR, T7, T9 |
ÆÇ¸Å°¡°Ý |
°¡°Ý¹®ÀÇ |
ºê·£µå |
Mettler-Toledo |
¿ø»êÁö |
½ºÀ§½º |