¿À´Ã º» »óǰ (4)
    °ßÀû¹®ÀÇ
    ½Ç½Ã°£°ßÀû
    ±â¼úÀÚ·á½Ç
    °øÁö»çÇ×
    Áú¹®°ú ´äº¯
    °í°´¼¾ÅÍ
    T.032-471-8801~2
    ¿ù - ±Ý : 09:00 ~ 18:00
    Á¡½É : 12:00 ~ 13:00
    Åä, ÀÏ, °øÈÞÀÏ ÈÞ¹«
    °í°´¼¾ÅÍ ¿¬°áÀÌ Àß µÇÁö¾ÊÀ»½Ã
    Q&A °Ô½ÃÆÇÀ» ÀÌ¿ëÇØÁÖ¼¼¿ä.

    Á¤¹ÐÇü pH / Àüµµµµ ¹ÌÅÍ, S213-Meter, S213-Standard(Kit), S213-Water(Kit)
    ÆÇ¸Å°¡°Ý 3,156,000¿ø
    ¿ø»êÁö ½ºÀ§½º
    ºê·£µå Mettler-Toledo
    Á¦Ç°ÄÚµå S213-Meter, S213-Standard
    º»Ç°¿É¼Ç¼±Åà  
    Ãß°¡¿É¼Ç¼±Åà  
    »ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦

    • Precise Benchtop pH-Conductivity Meter
    • Á¤¹ÐÇü pH / Àüµµµµ ¹ÌÅÍ

     

    Àüµµµµ, pH¸¦ µ¿½Ã¿¡ ÃøÁ¤ °¡´ÉÇÑ Dual Channel Meter
     TDS, ¿°ºÐ, ÀúÇ×, Àüµµµµ, pH¸¦ µ¿½Ã ¹× °¢°¢ ÃøÁ¤ °¡´É
     Çѱ¹¾î Áö¿ø (12°³ ¾ð¾î Áö¿ø)
     GLP ±Ô°Ý Áö¿ø
     IQ / OQ ¼­ºñ½º Á¦°ø (¿É¼Ç)
     IP54µî±Þ ¹æÁø/¹æ¼ö
     EasyDirect ¢â pH ¼ÒÇÁÆ®¿þ¾î : ¹ÙÄÚµå ¸®´õ, Űº¸µå, USB ½ºÆ½, USB ÇÁ¸°ÅÍ ¶Ç´Â PC ¿¬°á °¡´É

     uPlace ¼¾¼­ ½ºÅÄµå ¹× uMix ½ºÅÍ·¯ »ç¿ë °¡´É

     

     

     

     

    Model

    Çü½Ä

    Àü±Ø

    S213-Meter

    Meter only

    X

    S213-Standard(Kit)

    Basic

    InLab? Expert Pro-ISM & InLab?731-ISM

    S213-Water(Kit)

    Ãʼø¼ö¿ë

    InLab? Pure Pro-ISM & InLab? 741-ISM

     

     

    S213

    Measuring range (ÃøÁ¤¹üÀ§)

    Resolution(ÇØ»óµµ)

    Accuracy (Á¤È®µµ)

    pH

    -2.000 ¡¦ 20.000

    0.001/0.01/0.1

    ¡¾0.002

    mV

    -2000.0 ¡¦ 2000.0

    0.1/1

    ¡¾0.1 mV in -1000 ¡¦ 1000 mV; ¡¾0.2 mV outside

    Rel. mV

    -2000.0 ¡¦ 2000.0

    0.1/1

    ¡¾0.1 mV in -1000 ¡¦ 1000 mV; ¡¾0.2 mV outside

    Conductivity (ÀüµµÀ²)

    0.001 ¥ìS/cm ¡¦ 1000 mS/cm

    0.001 ¡¦ 1

    ¡¾ 0.5%

    TDS

    0.00 mg/L...1000 g/L

    0.01 ¡¦ 1

    0.01 ¡¦ 1

    Salinity (¿°µµ)

    0.00¡¦ 80.00 psu/ppt

    0.00 ¡¦ 1.0

    ¡¾ 0.5%

    Resistivity (ÀúÇ×·Â)

    0.00¡¦100.0 M¥Ø•cm

    0.00 ¡¦ 1.0

    ¡¾ 0.5%

    Conductivity ash (Àüµµ¼º ȸºÐ)

    0.000¡¦2022%

    0.001 ¡¦ 1

    ¡¾ 0.5%

    Temperature MTC/ATC

    -5.0 (-30.0) ... 130.0 ¡ÆC (MTC) ATC

    0.1 ¡ÆC

    ¡¾ 0.1 ¡ÆC

    Calibration

    (´«±Ý/º¸Á¤)

    Calibration points (º¸Á¤ ÁöÁ¡)

    Conductivity 1; pH Max. 5

    (ÀüµµÀ²1; pH ÃÖ´ëÄ¡. 5)

    Cond. Standards and Buffer groups

    (ÄÁµð¼Ç; Ç¥ÁØ/ ¿ÏÃæ±º)

    8 pre-defined pH buffers and 13 pre-defined

    Buffer recognition

    1 user defined each

    (»ç¿ëÀÚÁ¤ÀÇ)

    Isopotential point (µîÀüÀ§Á¡)

    pH 7.00

    Temperature capture

    Automatic and manual

    (ÀÚµ¿/ ¼öµ¿)

    Calibration reminder

    (º¸Á¤ ¾Ë¸²)

    User-configurable (»ç¿ëÀÚ ¼³Á¤)

    Electrode status icon

    (Àü±Ø »óÅÂ

    ¾ÆÀÌÄÜ)

    Shows quality of last calibration

    (¸¶Áö¸· º¸Á¤ÀÇ »óÅ ǥ½Ã)

    Manual input of cell constant

    (¼¼Æ÷ »ó¼öÀÇ ¼öµ¿ ÀÔ·Â)

    Yes

    Display of cell constant

    (¼¼Æ÷»ó¼öÀÇ Ç¥½Ã)

    In Conductivity and dual channel mode

    (Àüµµ¼º ¹× ÀÌÁß Ã¤³Î¸ðµå)

    Measurement

    (ÃøÁ¤)

    Choice of endpoint formats

    (Á¾Á¡ ±¸¼º¹æ½ÄÀÇ ¼±ÅÃ)

    Automatic, manual, timed

    (ÀÚµ¿, ¼öµ¿, ½Ã°£Á¦)

    Choice of stability criteria (pH only)

    (¾ÈÁ¤¼º ±âÁØ ¼±ÅÃ)

    Fast, standard, strict

    Choice of pH decimal places

    (pH ¼Ò¼öÁ¡ ¼±ÅÃ)

    1.111, 1.11, 1.1

    Temperature capture

    (¿ÂµµÄ¸ÃÄ)

    Automatic and manual

    (ÀÚµ¿/ ¼öµ¿)

    Serial measurements

    (¿¬¼ÓÃøÁ¤)

    Time interval, user-configurable
    (½Ã°£Á¦, »ç¿ëÀÚÁ¤ÀÇ)

    Choice of reference temperature

    (¿Âµµ ÀúÇ×·Â ¼±ÅÃ)

    20 ¡ÆC or 25 ¡ÆC

    Choice of temperature compensation

    (¿Âµµº¸»óÀÇ ¼±ÅÃ)

    Linear, non-linear, off, pure-water

    System and GLP

    Menu guidance

    (¼³¸í¼­¸Þ´º)

    12 languages (12°¡Áö ¾ð¾îÁö¿ø)

    Display color scheme

    (Ç¥½Ãâ »ö»ó)

    Blue, red, green, grey

    Time and date

    (½Ã°£ ¹× ³¯Â¥)

    2 time formats, 4 date formats

    (2°³ÀÇ ½Ã°£Çü½Ä, 4°³ÀÇ ³¯Â¥»óÅÂÁö¿ø)

    PIN protection

    (PIN º¸È£)

    Login, deletion of data, system settings

    (·Î±×ÀÎ, ³¯Â¥»èÁ¦, ȯ°æ¼³Á¤)

    Measurement limits

    (ÃøÁ¤Á¦ÇѹüÀ§)

    User-defined

    (»ç¿ëÀÚÁ¤ÀÇ)

    Instrument modes

    (°èÃø±â¸ðµå)

    Routine mode / expert mode

    (ÁÖ±âÀû¸ðµå, Àü¹®°¡¸ðµå)

    ID input

    (ÀÔ·Â ID)

    User ID, sample ID, sensor ID, sensor

    ID input automation

    (ÀÔ·Â ID ÀÚµ¿)

    Barcode reader and keyboard (USB)

    Regulations

    Pure & ultra-pure water (Ãʼø¼ö)

    USP/EP compliant

    Bioethanol

    (¹ÙÀÌ¿À¿¡Åº¿Ã)

    ABNT NBR 10547:2006

    Sugar analysis

    (´çºÐ ºÐ¼®)

    ICUMSA GS2/3-17 and GS 1/3/4/7/8-13

    Data processing

    (µ¥ÀÌÅͰúÁ¤) 

    Data storage

    (µ¥ÀÌŸÀúÀå)

    2000 measurements

    Print formats

    (Ãâ·ÂÇüÅÂ)

    Short, normal, GLP

    Data Export

    (µ¥ÀÌÅͼÛÃâ)

    USB-stick, EasyDirect pH PC software

    Connectors

    (¿¬°áÀåÄ¡)

     

    pH Sensor input

    (pH¼¾¼­)

    BNC (impedance > 3x1012 ¥Ø)

    Temperature sensor input

    (¿Âµµ¼¾¼­)

    Cinch/RCA (NTC30 k¥Ø or Pt1000)

    Reference input

    (Ç¥ÁØ)

    2 mm Ref.

    Digital sensor input

    (µðÁöÅÐ ¼¾¼­)

    Mini-LTW

    Conductivity input

    (Àüµµ¼º)

    Mini-DIN

    Conductivity input

    RS232, USB-A, USA-B

    Stirrer connector

    (±³¹Ý±â ¿¬°áÀåÄ¡)

    Mini-DIN

    General

    Power requirements

    (ÇÊ¿äÀü·Â)

    DC 912 V/ 2.5 W

    Size/weight

    (Å©±â/¹«°Ô)

    204 x 174 x 74 mm, 890 g

    Display

    (Ç¥½Ãâ)

    Color TFT

    Ambient conditions

    (ȯ°æÁ¶°Ç)

    Temperature

    (¿Âµµ)

    5 ¡¦ 40 ¡ÆC

    Relative humidity

    (ÁÖº¯½Àµµ)

    5 ¡¦ 80% (non-condensing)

    Installation category

    II

    Pollution degree

    (¿À¿°Á¤µµ)

    2

    Altitude

    (°íµµ)

    Up to 2000 m above sea level

    Protection level

    (º¸È£·¹º§)

    IP54

    Housing

    ABS/PC reinforced

    Window

    Polymethyl methacrylate (PMMA)

    Keypad

    Membrane keypad: Polyethylene terephthalate (PET)

     

     

     

    Sensors for SevenCompact¢â Conductivity

    Model

    Description

    30014092

    InLab 731-ISM, 4-electrode graphite conductivity sensor, ATC

    30014094

    InLab? 741-ISM, 2-electrode steel conductivity sensor, ATC

    30014097

    InLab? Trace, high-accuracy sensor for low conductivities, ATC

    30014098

    Flow-Cell for InLab? Trace


    Sensors for SevenCompact¢â pH

     

     

    Model

    Description

    30014096

    InLab Expert Pro-ISM, rugged 3-in-1 pH sensor, PEEK shaft, ATC

    51344055

    InLab? Routine Pro-ISM, 3-in-1 pH sensor, glass shaft, ATC, refillable

    51344163

    InLab? Micro Pro-ISM, 3-in-1 pH sensor, glass shaft, 5 mm shaft diameter, ATC,

    51344172

    InLab? Pure Pro-ISM, 3-in-1 pH sensor, glass shaft, immovable glass sleeve, ATC, refillable

    51344072

    InLab? Science Pro-ISM, 3-in-1 pH sensor, glass shaft, movable glass sleeve, ATC, refillable

    51344155

    InLab? Solids Pro-ISM, 3-in-1 pH sensor, glass shaft, open junction, sharp membrane, ATC

    30281896

    ISM? cable 1.2 m, BNC/RCA-MultiPin¢â

     

    pH buffers and conductivity standard solutions

     

    Model

    Description

    51302049

    1413 ¥ìS/cm standard conductivity solution in side-sealed sachets, 30 x 20 mL

    51302050

    12.88 mS/cm standard conductivity solution in side-sealed sachets, 30 x 20 mL

    51302069

    pH 4.01 buffer solution in side-sealed sachet, 30 x 20 mL

    51302047

    pH 7.00 buffer solution in side-sealed sachets, 30x20 mL

    51302070

    pH 9.21 buffer solution in side sealed sachets, 30x20 mL

    51302079

    pH 10.00 buffer solution in side sealed sachets, 30x20 mL

     

    »óǰÁ¤º¸°í½Ã
    Á¦Ç°¸í Á¤¹ÐÇü pH / Àüµµµµ ¹ÌÅÍ, S213-Meter, S213-Standard(Kit), S213-Water(Kit)
    ÆÇ¸Å°¡°Ý 3,156,000¿ø
    ºê·£µå Mettler-Toledo
    ¿ø»êÁö ½ºÀ§½º
    °ü·Ã»óǰ
    À§ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù.
    »ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óǰÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óǰ¹®Àǰ¡ ¾ø½À´Ï´Ù.
      »óǰ¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
    ¹Ýǰ±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆÇ¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óǰ±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óǰ °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹Ýǰ½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óǰÀ» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ·Ôµ¥Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà Åù蹫·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)

    È­¹°(¿ë´Þ),Äü ÀÌ¿ëÀº ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷     ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ32     ´ëÇ¥ÀÚ : À±´ÙÀº, ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 (Á¤º¸È®ÀÎ)
    Åë½ÅÆÇ¸Å¾÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ : 121-86-02196     °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆÃ¼­ºñ½ºÁ¦°ø¾÷ü :