    Ź»ó¿ë ¼öÁúÃøÁ¤±â, 3505 ,3510 ,3520 , Bench pH Meters , Ź»ó¿ë PH¸ÞŸ , Ź»ó¿ë ÀüµµµµÃøÁ¤±â ,Àüµµµµ, ÀúÇ×·ü, TDS, ¿°µµ
    ÆÇ¸Å°¡°Ý 1,132,000¿ø
    ¿ø»êÁö ¿µ±¹
    ºê·£µå JENWAY
    Á¦Á¶»ç JENWAY
    Á¦Ç°ÄÚµå 351 001
    »ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦









    3505, 3510 and 3520 Bench pH Meters


    ÀüµµÀ², ÀúÇ×·ü µîÀ» ÃøÁ¤ÇØ ÁÖ´Â ±â±â

    • Àüµµµµ, ÀúÇ×·ü, TDS, ¿°µµ ¸ðµå ¼³Á¤ °¡´É
    • ±Øµµ·Î ³·Àº Àüµµµµ ÃøÁ¤À» À§ÇÑ Ç»¾î¿öÅÍ ¸ðµå
    • µ¥ÀÌÅÍ ±â·ÏÀåÄ¡¿¡ 500°³ÀÇ °á°ú°ª ÀúÀå °¡´É
    • PCÀü¿ë ÇÁ·Î±×·¥ ¹× ÇÁ¸°ÅÍ ¿¬°á °¡´É
    <4510>
    • µ¿½Ã¿¡ ÀüµµÀ²,TDS, ¿Âµµ¸¦ º¸¿©ÁÜ
    • °¡Àå ÃÖ°í resolution ÀÚµ¿¼±ÅÃ
    • ¼¿ »ó¼ö³ª Ç¥ÁØ¿ë¾× ±³Á¤
    • ÀÚµ¿ Ç¥ÁØÀÎÁö
    <4520>
    • ÀüµµÀ², ÀúÇ×·ü, TDS, ¿°µµ ¸ðµå
    • ³·ÀºÀüµµÀ² ÃøÁ¤À¸·Î ÀÎÇÑ Á¤Á¦¼ö¸ðµå
    • 500°³ÀÇ µ¥ÀÌÅÍ °á°ú ÀúÀå°¡´É

    Bench Conductivity Meters / º¥Ä¡Çü Àüµµµµ ÃøÁ¤±â

    Cat No.

    451001

    452001

    Parameter

    4510

    4520

    Conductivity range

    6 autoselected from 0 to 1999mS*

    6 autoselected from 0 to 19.99S*

    Conductivity resolution

    0.01¥ìS to 1mS

    6 autoselected from 0 to 19.99S*

    Conductivity accuracy

    ¡¾0.5% ¡¾2 digits

    ¡¾0.5% ¡¾2 digits

    Automatic standard recognition

    10¥ìS, 84¥ìS, 1413¥ìS, 12.88mS

    10¥ìS, 84¥ìS, 1413¥ìS, 12.88mS

    Cell constant

    0.010 to 19.999

    0.010 to 19.999

    TDS range

    6 auto-selected from 0-1999g/l*

    6 auto selected ranges from 0-1999g/l*

    TDS resolution

    0.01mg/l to 1g/l

    0.01mg/l to 1g/l

    TDS accuracy

    ¡¾0.5% ¡¾2 digits

    ¡¾0.5% ¡¾2 digits

    EC Ratio

    0.50 to 0.80

    0.50 to 0.80

    Resistivity range

    NA

    0-20Mohm

    Resistivity resolution

    NA

    0.01Mohm

    Resistivity accuracy

    NA

    ¡¾0.5% ¡¾2 digits

    Salinity range

    NA

    0-99.9g/l

    Salinity resolution

    NA

    0.1g/l

    Salinity accuracy

    NA

    0-35 ¡¾1g/l, 35-99.9 ¡¾3g/l

    ATC and manual

    0 to 100¡ÆC

    0 to 100¡ÆC

    Temperature coefficient

    0.00% to 4.00%/¡ÆC

    0.00% to 4.00%/¡ÆC

    Reference temperature

    18, 20 or 25¡ÆC

    18, 20 or 25¡ÆC

    GLP

    NA

    Calibration reminder interval, alarm outputs and security code protected data

    Outputs

    Analogue and RS232

    Analogue, RS232 and IrDA interface

    Connector

    7-pin DIN

    7-pin DIN

    Power

    9V AC ¡¾10% @ 50/60Hz

    9V AC ¡¾10% @ 50/60Hz

    Size (l x w x d)

    210 x 250 x 55mm

    210 x 250 x 55mm

    Weight

    850g

    850g

    3505


    • General purpose education laboratory pH measurement meter
    • Intuitive operation via rotary controls
    • pH, temperature and mV mode for redox and electrode diagnosis
    • Calibration controls locked during measurement
    • Manual or automatic temperature compensation
    • Large display
    • Battery or mains operated
    • 3 year warranty
    The 3505 is a simple to use laboratory pH, mV and temperature meter for use in general purpose and educational applications. It utilises rotary controls for mode selection and pH calibration. A novel design feature ensures that inadvertent movement of the calibration controls has no effect during sample pH measurement. The large display ensures that during demonstrations and when used by groups, all can easily see the clear LCD readout.

    view video
    3510

    • Simultaneous readout of pH and temperature
    • pH resolution to 3 decimal places
    • 1, 2 or 3 point calibration
    • Automatic or manual buffer selection
    • Storage of up to 32 results
    • RS232 connection to printer or PC via DataWay
    • 3 year warranty

    The 3510 is a versatile, simple to use pH, mV and temperature meter that is ideal for routine analysis. With up to three decimal place resolution and a choice of up to three calibration points the 3510 provides the user with added flexibility where future demands for enhanced performance may be required. A choice of pH calibration buffers to DIN, JIS and NIST standards can be used for automatic calibration, as well as manually entered buffer values. The pH measurement meter also has the ability to store up to 32 results.

    3520

    • Ideal for quality control and GLP applications
    • Up to 3 decimal place resolution
    • 1, 2 or 3 point pH calibration
    • Automatic or manual buffer selection
    • Multiple language options
    • Storage of up to 500 results
    • RS232 connection to printer or PC or infra red (IrDA) communication
    • GLP compliant
    • 3 year warranty

    The 3520 dynamic pH/mV meter offers research grade specifications with a comprehensive range of features and functions, making it suitable for the broadest range of research, general laboratory, QC and GLP based applications. The built in data logger can store, print or output readings based on a wide range of trigger options, making this model suitable for monitoring and controlling pH levels.

    Technical Specification


    Parameter 3505 3510 3520
    pH range –2.00 to +16.00 –2.000 to +19.999 –2.000 to +20.000
    pH resolution 0.01 0.001/0.01/0.1 0.001 / 0.01 / 0.1
    pH accuracy ¡¾0.02 ¡¾0.003 ¡¾0.003
    Calibration Manual 2 point User selectable 1, 2 or 3 point User selectable 1, 2 or 3 point
    Automatic buffer recognition Not available Jenway (2.00, 4.00, 7.00, 9.20 and 10.00), DIN, NIST, JIS Jenway (2.00, 4.00, 7.00, 9.20 and 10.00), DIN, NIST, JIS
    mV range ¡¾1999mV ¡¾1999.9mV ¡¾1999.9mV
    mV resolution 1mV 0.1/1mV 0.1/1mV
    mV accuracy ¡¾1mV ¡¾0.2mV ¡¾0.2mV
    Temperature range –10 to +105¡ÆC –10 to 105¡ÆC –10 to 105¡ÆC
    Temperature resolution 0.1¡ÆC 0.1¡ÆC 0.1¡ÆC
    Temperature accuracy ¡¾0.5¡ÆC ¡¾0.5¡ÆC ¡¾0.5¡ÆC
    ATC range 0 to 100¡ÆC 0 to 100¡ÆC 0 to 100¡ÆC
    Alarm points –2.000 to 19.999pH
    GLP Calibration reminder interval (1 to 999hrs) Alarm outputs (open collector and audible). Security code protected data
    Outputs Analogue and RS232 Analogue, RS232 and IrDA
    Connector BNC BNC BNC
    Power 9V PP3 battery as standard or optional 9V power supply 9V AC ¡¾10% @ 50/60Hz 9V AC ¡¾10% @ 50/60Hz
    Size (l x w x d) 210 x 250 x 55mm 210 x 250 x 55mm 210 x 250 x 55mm
    Weight 850g 850g 850g


    Ordering Information
    230V Versions - UK Power supply


    Part Code Description
    351 001 3510 pHmV meter supplied with glass combination pH electrode (924 005), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH 4, 7 and 10 buffers and UK power supply
    352 001 3520 pHmV meter supplied with glass combination pH electrode (924 005), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH 4, 7 and 10 buffer sachets and UK power supply

    230V Versions - EU Power supply


    Part Code Description
    351 201 3510 pH/mV meter supplied with glass combination pH electrode (924 005), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH 4, 7 and 10 buffers and EU power supply
    352 201 3520 pH/mV meter supplied with glass combination pH electrode (924 005), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH 4, 7 and 10 buffer sachets and EU power supply

    110V Versions


    Part Code Description
    351 101 3510 pH/mV meter supplied with glass combination pH electrode (924 005), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH 4, 7 and 10 buffers and US power supply
    352 101 3520 pH/mV meter supplied with glass combination pH electrode (924 005), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH 4, 7 and 10 buffer sachets and US power supply

    »óǰÁ¤º¸°í½Ã
    Á¦Ç°¸í Ź»ó¿ë ¼öÁúÃøÁ¤±â, 3505 ,3510 ,3520 , Bench pH Meters , Ź»ó¿ë PH¸ÞŸ , Ź»ó¿ë ÀüµµµµÃøÁ¤±â ,Àüµµµµ, ÀúÇ×·ü, TDS, ¿°µµ
    ÆÇ¸Å°¡°Ý 1,132,000¿ø
    ºê·£µå JENWAY
    ¿ø»êÁö ¿µ±¹
    Á¦Á¶»ç JENWAY
    °ü·Ã»óǰ
        
    »ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óǰÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óǰ¹®Àǰ¡ ¾ø½À´Ï´Ù.
      »óǰ¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
    ¹Ýǰ±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆÇ¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óǰ±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óǰ °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹Ýǰ½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óǰÀ» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ·Ôµ¥Åù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà Åù蹫·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)

    È­¹°(¿ë´Þ),Äü ÀÌ¿ëÀº ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : (ÁÖ)¿¡ÀÌÄ¡¿ÍÀÌ»ê¾÷     ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ32     ´ëÇ¥ÀÚ : À±´ÙÀº, ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 121-86-02196 (Á¤º¸È®ÀÎ)
    Åë½ÅÆÇ¸Å¾÷½Å°í : Á¦2015-ÀÎõ°è¾ç-0634È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ : 121-86-02196     °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆÃ¼­ºñ½ºÁ¦°ø¾÷ü :